Reflex Level Gauges

Features



  • Reflex level guage applicable upto 200 kg/cm and upto 400 deg cent
  • Cryo applications upto -196 deg cent
  • Toughened borosilicate glass with serrations
  • For applicability in critical, acidic, cryo and temperature zone
  • IBR certified device available
  • NACE, H2S service compatibility applicable
  • Non frost extension
  • Heat tracing available
  • Applicable for refinery, petrochemical, chemical, power, radioactive, fertilizer, food, pharma, metal industry applications

We are leading Reflex Level Gauges Manufacturers in Mumbai, India



  • Specifications
  • How to Order
  • Enquiry
  • Download Pdf



Specifications
Type of Gauge a) Low Pressure - 30kg/cm2 b) Medium Pressure - 100kg/ cm2 c) High Pressure - 200kg/ cm2
Mounting Orientation Top - Bottom Vertical Side - Side Right Side - Side Left Side - Side Back (Right/Left)
Temperature Upto 400 C
CCD Max. upto 3000mm
Liquid Chamber In forged construction: Carbon steel, SS304, SS304L, SS316, SS316L, Monel, Titanium, Inconnel 600, Hastelloy C, Polypropylene, Other on request (subject to pressure & Temperature Condition)
Cover Plate In forged construction: Carbon steel, SS304, SS304L, SS316, SS316L, Monel, Titanium, Inconnel 600, Hastelloy C, Polypropylene
Cushion CAF, PTFE, Grafoil with SS prignated
Gasket CAF, PTFE, Grafoil with SS prignated
Fastner 1SS, ASTM A 193 Gr B7 / A194 Gr 2H / Anodized Aluminium (for PP moc)
Scale Aluminium anticorossion powder coated and SS engraved in mm
Glass Applicable till 320°C as per DIN 708/ 7081, BS 3463, JS B 8211, Toughened Borosilicate glass
Process Connection Screwed / Flanged / Socket Weld and other on request
Isolation Valve Auto Ball Check Valve 2
a) Screwed Bonnet offset construction suitable upto 50 kg/cm 2
b) Bolted Bonnet offset construction suitable above 50 kg/cm
c) Material Construction as per wetted part
Vent ½” Plugged ½” Needle Valve ½” Ball Valve ½” Globe Valve ½” Gate Valve
Drain ½” Plugged ½” Needle Valve ½” Ball Valve ½” Globe Valve ½” Gate Valve
Optional a) Non-Frost Extension for extreme low temperature application
b) Heating Jacket - to read the level of high congelable or ebullient liquid
c) IBR Certification