Displacer type level transmitter

Float Operator Level Transmitters

Features


  • Displacer type level transmitter with application upto 100 bar and 350 deg cent application
  •  Heavy walled floats for critical application
  •  Tight sealing versions for float sensors with level transmitter to enable correct application solutions, with sealing internals at 10(-3/-4) mbarltr/sec available
  •  Insertion length defined for 5000mm, other lengths on request and confirmation on design
  • Durability defined on sealing and pressure and temperature application
  • Improved reliability with dual opposed magnet design which provides snap action
  • Applicable with various versions of MOC's depending on pressure and temperature, versions with Stainless and steel, hastealloy, monel, PTFE, PP, Titanium available
  •  Versions with flange, screwed, welded available
  • IBR versions available
  • Applicable for H2S, NACE, certified
  • Radiography level - 1 versions available
  • Level transmitter is CCOE approved and certified for IP67, IP65
  • Certified for group IIA/IIB, IIC
  • Enclosure at die cast alluminium and SS available
  • Application with PTFE lined at special 1.6 mm thickness and PTFE floats for critical media available
  • Versions with ATEX and FM certified available on request


  • Specifications
  • Enquiry
  • Download Pdf


Float PTFE, PP, PVDF, SS316, SS304, SS316L, SS304L, Monel, Titanium, hastealloy
Float stem PTFE lined SS, PP lined SS, PVDF lined SS, SS316, SS304, SS316L, SS304L,
Monel, Titanium, hastealloy
Flange PTFE, PP, PVDF, SS316, SS304, SS316L, SS304L, Monel, Titanium,
cast carbon steel, hastealloy
Switch enclosure Die cast alluminium, SS304, SS316, SS316L
Cable gland
Brass, PBS plastic, SS316, SS304, 316L
Stopper Metal stoppers of relavant material compatible to media





tr>
Float 38X200mm upto 60X160mm and upto 68X100mm
Float Specific gravity = 0.4, till 1.2
Float stem 500mm to 5000mm, other lengths on request and confirmation on design
Monel, Titanium, hastealloy
Float stem widh 12.5mm and 16mm
Monel, Titanium, hastealloy
Float Pressure design till 40 kg / 60 kg / 100 kg
cast carbon steel, hastealloy
Flange rating max rating ANSI 600# and DN PN 100
cast carbon steel, hastealloy
Cable gland Double compression, metal cable normal glands, ½” NPT F, ¾” ET, M20, PG 13.5, PG16
cast carbon steel, hastealloy
Flange Forged, cast versions, radiography level - 1 / 2 versions available
cast carbon steel, hastealloy
Float weight 60gms to 200 gms depending specific gravity
cast carbon steel, hastealloy
Float stem weight Max upto 200 gms depending on size / length
cast carbon steel, hastealloy
Flange weight 500gms till 30 kg depending float dimensions which inturn would density of media and other accessories
cast carbon steel, hastealloy
Temperature application -100 deg cent till 350 deg cent
cast carbon steel, hastealloy
Pressure application 2 Upto 100 kg/cm g
cast carbon steel, hastealloy
Analog transmitter output 4- 20 m A
cast carbon steel, hastealloy
Analog transmitter principle Reed switch
cast carbon steel, hastealloy
Analog transmitter power supply 230 VAC, 5 A or 24VDC, 0.5 A
cast carbon steel, hastealloy
Analog transmitter out put in split range Split range of 4„1¤712 m A and 12„1¤720 m A, others on request
cast carbon steel, hastealloy
Analog transmitter internal resistance 200M ohms
cast carbon steel, hastealloy
Transmitter accuracy 3%
cast carbon steel, hastealloy
Transmitter repeatability 0.15%
cast carbon steel, hastealloy
Transmitter certifications CCOE, FM, ATEX, CE (versions applicability on request)
cast carbon steel, hastealloy
Transmitter enclosure EExia IICT6, Eexd IIA/IIB, Eexd IIC and IP65 >
HART transmitter principle
Reed switch, LVDT
HART transmitter accuracy 1.5 % >
HART transmitter output in split range Adjustable as per HART software >
HART programmable software With serial inter face adapter with HART inter face to calibrate >
HART transmitter feature SIL2 cer tified >
HART transmitter feature Slave circuitry operation with MASTER as an additional option on request >
HART transmitter enclosure EExia IICT6, EExd IIA/IIB, EExd IIC and IP65 >
HART transmitter certifications CCOE, FM, ATEX, CE (Versions applicability on request) >