Bourdon Sensing Pr. Gauges - 250mm

BS25 / LFBS25 / SFBS25 / LSBS25

Features


  • Compliance to latest EN - 837 standard
  • Range: (-) 1600 kg/cm2
  • Bourdon in SS316 Ti as standard providing better mechanical properties guaranteeing repeatability & accuracy
  • Accuracy ±1% FSD (standard), ±0.5% FSD on request
  • Uni of measurement - kg/cm2, bar, PSI, KPa, MPa




  • Specifications
  • How to Order
  • Enquiry
  • Download Pdf



Specifications
Ref. standard EN - 837
Dial 250 mm in aluminium, white background, black markings
Case SS304 / SS316 with bayonet bezel
Protection IP-67 (IS: 13947 part I / IEC: 60529)
Window Safety glass (shatter proof / toughened glass)
Bourdon SS316, SS316 Ti, SS316L, Monel
Socket 22mm Square in SS316, SS316 Ti, SS316L, Monel
Movement SS304, SS316
Range As per EN - 837 (refer table) minimum span
0.6 kg/cm2, maximum 1600 kg/cm2
Connection 1/2" NPT (M) as standard (other optional)
Accuracy ± 1.0% FSD standard (± 0.5% FSD on request)
Over range As per EN - 837
Suitability (-) 20°C to 80°C (service temperature)
Zero adjustment Micrometer Pointer
Blow out disc Provided (on top)
Temperature suitability Ambient (-)20°C to 60°C, Media 200°C
Temperature Effect Within ±0.4% FSD/10°C, when temperature changes from reference temperature of 20°C (as per EN-837 standard) IBR cer tification
Optional IBR certification

NACE compliance

Liquid Filled Case

External Knob for zero setting

Vacuum Protection
Gauge Bar, kg/cm2 Least count
Vacuum (-)1 to 0
-760 to 0mmHg
0.02
20
Compound (-)1 to 0.6 0.05

(-)1 to 1.5 0.05

(-)1 to 3 0.10

(-) 1 to 5 0.10

(-)1 to 9 0.20

(-)1 to 15 0.50

(-)1 to 24 0.50

(-)1 to 39 1.0
Pressure Gauge 0 to 0.6 0.01
('C' shaped Bourdon) 0 to 1 0.02

0 to 1.6 0.05

0 to 2.5 0.05

0 to 4 0.10

0 to 6 0.10

0 to 10 0.20

0 to 16 0.50

0 to 25 0.50

0 to 40 1.0

0 to 60 1.0
Pressure 0 to 100 2.0
Gauge 0to 160 5.0
Coil type 0to 250 5.0
Bourdon 0to 400 10.0

0to 600 10.0

0to 800 20.0

0to 1000 20.0

0to 1600 50.0